INQUIRE CURVE FACILITIES
-
CALL SEQUENCE
CALL PQCVF (WTYPE, NRCACT, ERRIND, MNUBSC, NCACT, CACT)
INPUT PARAMETERS
- INTEGER WTYPE
- Workstation type
- INTEGER NRCACT
- List element requested of curve approximation criteria types
OUTPUT PARAMETERS
- INTEGER ERRIND
- Error indicator
- INTEGER MNUBSC
- Maximum non-uniform b-spline curve order supported
- INTEGER NCACT
- Number of available curve approximation criteria types
- INTEGER CACT
- Nth element of list of available curve approximation criteria types
PHIGS STATE
(PHOP,*,*,*)
EFFECT
Returns the curve facilities offered by workstations of type WTYPE.
If the inquired information is available, the error indicator is returned as 0
and values are returned in the output parameters.
If the inquired information is not available, the values returned in the output
parameters are implementation dependent and the error indicator is set to one
of the following error numbers to indicate the reason for non-availability:
ERRORS
- 2
Ignoring function, function requires state (PHOP, *,*,*)
- 52
- Ignoring function, workstation type not recognized by the implementation
- 51
- Ignoring function, this information is not yet available for this generic
workstation type: open a workstation of this type and use the specific
workstation type
- 59
- Ignoring function, the specified workstation does not have output
capability (i.e. the workstation category is neither OUTPUT, OUTIN, nor MO)
- 62
- Ignoring function, this information is not available for this MO
workstation type