Previous Next Up Title Contents General Index Functions Index Bookshelf

INITIALIZE CHOICE

PINCH


CALL SEQUENCE

PINCH (WKID, CHDNR, ISTAT, ICHNR, PET, XMIN, XMAX, YMIN, YMAX, LDR, DATREC)

INPUT PARAMETERS

INTEGER	WKID
INTEGER	CHDNR
INTEGER	ISTAT
INTEGER	ICHNR
INTEGER	PET
REAL	XMIN,XMAX,YMIN,YMAX
INTEGER	LDR
CHARACTER*80	DATREC(LDR)

ARGUMENTS

WKID
Workstation identifier.
CHDNR
CHOICE input device identifier.
ISTAT
Choice initial state:
ICHNR
Choice initial value.
PET
Echo type.
XMIN,XMAX,YMIN,YMAX
Echo area in DC.
LDR
Number of data records.
DATREC(LDR)
Data record.

PHIGS STATE

(PHOP, WSOP, *, *).

EFFECT

This function restricts the 3D initialize choice function to 2D.

ERRORS

3
Ignoring function, function requires state (PHOP, WSOP,*,*)
54
Ignoring function, the specified workstation is not open
61
Ignoring function, specified workstation is neither of category INPUT nor of category OUTIN
250
Ignoring function, the specified device is not available on the specified workstation
251
Ignoring function, the function requires the input device to be in REQUEST mode
254
Ignoring function, invalid echo area volume: XMIN>=XMAX, YMIN>=YMAX
255
Ignoring function, one of the echo area volume boundary points is outside the range of the device
253
Ignoring function, the specified prompt echo type is not available on the specified workstation
260
Ignoring function, one of the fields within the input device data record is in error
261
Ignoring function, initial value is invalid

SEE ALSO

initialize choice 3, set choice mode, request choice, sample choice, get choice, inquire choice device state, inquire default choice device state, inquire number of available logical input devices