Previous Next Up Title Contents Index Functions Index Top Library

NITIALIZE STROKE

PINSK


CALL SEQUENCE

PINSK(WKID, SKDNR, IVIEWI, N, IPX, IPY, PET, XMIN, XMAX, YMIN, YMAX, LDR, DATREC)

INPUT PARAMETERS

INTEGER	WKID
INTEGER	SKDNR
INTEGER	IVIEWI
INTEGER	N
REAL	IPX(N), IPY(N)
INTEGER	PET
REAL	XMIN, XMAX, YMIN, YMAX
INTEGER	LDR
CHARACTER*80	DATREC(LDR)

ARGUMENTS

WKID
Workstation identifier.
SKDNR
STROKE input device identifier.
IVIEWI
View index.
N
Number of initial points.
IPX(N), IPY(N)
Stroke initial points.
PET
Echo type.
XMIN, XMAX, YMIN, YMAX
Echo area.
LDR
Number of data records.
DATREC(LDR)
Data record.

PHIGS STATE

(PHOP, WSOP, *, *).

EFFECT

Restricts the 3D initialize stroke function to 2D.

ERRORS

3
Ignoring function, function requires state (PHOP, WSOP,*,*)
54
Ignoring function, the specified workstation is not open
61
Ignoring function, specified workstation is neither of category INPUT nor of category OUTIN
250
Ignoring function, the specified device is not available on the specified workstation
251
Ignoring function, the function requires the input device to be in REQUEST mode
254
Ignoring function, invalid echo area volume: XMIN>=XMAX, YMIN>=YMAX
255
Ignoring function, one of the echo area volume boundary points is outside the range of the device
253
Ignoring function, the specified prompt echo type is not available on the specified workstation
260
Ignoring function, one of the fields within the input device data record is in error
261
Ignoring function, initial value is invalid
262
Ignoring function, number of points in the initial stroke is greater than the buffer size
114
Ignoring function, the view index value is less than zero

SEE ALSO